网站头部语言

Time of issue:2021-12-02 12:05:45
Product
Provide customers with products and services from material blanking to surface treatment and installation

PRODUCTS

Number of views:
1000

SF6 gas recovery device

Brand: DILO
Model: DILO-B120R21
Theoretical compression capacity of compressor: 5.7m3/h (200cfh)
Compressor final pressure value: 50bar (725psi). Vacuum Pump: <2x10-3 mbar (<1.5xlO-3 mm Hg)
Final vacuum degree of vacuum compressor: ﹤50mbar (﹤37.5mm Hg)
Retail price
0.0
Market price
0.0
Number of views:
1000
Product serial number
Quantity
-
+
Stock:
0
Product description
Parameters

SF6 gas recovery device (DILO-B120R21)

Imported from Germany DILO, the world's best-selling; quality assurance, 6 major functions in one!

Overview

SF6 gas recovery device (DILO-B120R21) is one of the products of German DILO company with advanced technology and excellent recovery performance. Weavers has established a good cooperative relationship with it, has full agency rights, and provides its spare parts and continuous guarantee services. . WIFOSS has promoted and applied the DILO-B120R21 SF6 gas recovery device to the entire Asia-Pacific region, bringing more professional SF6 gas recovery devices and a full range of product problem solving strategies to users in the Asia-Pacific region.

Equipment introduction

The device consists of the following components:

  • Electrical control: Power sockets installed in the control cabinet generate power. (The correct phase is monitored by the steering sensor controller). All indicator lights and buttons are marked and installed in the control cabinet door. The running time is indicated by the working time counter. The operating panel inside the control cabinet door has two functions. 1. Displays the gas flow for the preselected automatic function. 2. Manually open the valve via the illuminated pushbutton display.
  • Manual operation: Turn the "Functions" switch to "0: Manual operation" for manual operation. All valves are preselected individually (LEDs flashing) via the built-in illuminated pushbuttons. If a wrong valve is selected, all selected valves can be restarted via "Reset Valves" (LEDs off). The preselection valve can be opened via the "Open valve" button (LEDs light up). The solenoid valve can be opened upwards from the evaporator only when the evaporator reaches operating temperature (only for liquid storage). The solenoid valve can only be opened from the vacuum pump when no overpressure exists while the vacuum pump is evacuating. Note: When using the "0: Manual operation" function, the operation is reliable for its own correct gas handling.
  • True suffocation pump: The vacuum pump and vacuum measuring device have been protected against overpressure. Therefore, damage to the instrument due to overvoltage can be avoided. The solenoid valve can only be opened from the vacuum pump when there is no overpressure while the vacuum pump is evacuating. If this solenoid valve is preselected with other solenoid valves, they cannot be opened either. Reduction of SF6 gas overpressure in compressors and vacuum compressors has been described in the description of the "Gas Recovery" function. Release air and nitrogen through the vent valve. The vacuum pump is only vented to atmosphere.
  • Compressor: The compressor is a dry compressor and operates without oil, which produces different outputs and different final pressures. The air tightness of the compressor piping should be absolutely intact. But the maintenance of the compressor will be easier to implement. Overpressure operation can be controlled by a pressure reducer and a contact meter.
  • Vacuum Compressor: Dry-running vacuum compressors are protected during operation by regulators, solenoid valves and check valves. When the gas is recovered, the vacuum compressor is in the state of automatic switch.
  • Filter drier, particle filter: SF6 gas is purified by the particle filter in the device and dried through the filter drier. The SF6 gas passes through these filters in every gas treatment process.
  • Maintenance of storage containers -: SF6 is stored in gaseous form and can also be stored in liquid form under corresponding high pressure conditions. How to distinguish the storage state in the pressure tank: gaseous at 25bar (360psi), liquid at 50bar (725psi) (Note! Pressure vessels cannot be used for the transportation of SF6 gas). It should be stored in a transport bottle for transport. SF6 for liquid storage can be viewed from the weight indicator.

 

 

 

 

Service Guarantee

  • Provide on-site training guidance and conduct on-site demonstration operations.
  • Provide detailed Chinese manual and user guide.
  • One year free warranty, lifetime spare parts support and maintenance.
  • User file information management, customer service department return visit and follow-up service every six months.
  • The hotline is available 365 days a day to answer user inquiries.
Scan the QR code to read on your phone
We could not find any corresponding parameters, please add them to the properties table
Previous
Next
Username used for comment:
客户留言
Description:
验证码
韦弗斯检测技术

Service Line:400-668-3536
Robte : 13585763546
Tel:+86-21-60195869
E-mail:SF6@winfoss.com

Quick Navigation

Subscribe to News

If you are interested in our products, you can follow us!

Follow Us
feedback feedback feedback feedback

底部版权

Time of issue:2021-11-25 13:36:06

Privacy Statement  Terms and Conditions  Copyright © Winfoss Seeker Technology (Shanghai) Co., Ltd. All  沪ICP备15031711号 沪公网安备31011802004953号 Power By:www.300.cn

搜索
Search