SF6 micro water density online monitoring device

SF6 micro water density online monitoring device (WINFOSS-S6) Original imported sensor, precise measurement, long life; patented sealing technology, zero leakage, effectively ensure the safety of high-voltage equipment! product description The SF6 micro-water density online monitoring device (WINFOSS-S6) is mainly used in the online monitoring of high-voltage electrical equipment using SF6 gas insulation in substations. The SF6 micro-water density online monitoring device can monitor the SF6 gas pressure, Density, temperature, dew point and PPM values. And provide SF6 gas moisture exceeded alarm function, density alarm. The data processing server automatically collects and stores monitoring data, and completely preserves the data trend (the data can be preserved for more than 15 years). The data processing server displays and processes the received data, and gives the test results and the change trend curve. The monitoring data and alarm signals can be uploaded to the upper-level monitoring center or the background of the fortune monitoring in real time. SF6 micro-water density online monitoring device (WINFOSS-S6) transmission monitoring unit integrates three sensors and a micro-circulation system. The SF6 micro-water density online monitoring product in high-voltage switchgear mainly solves the problem of online monitoring of micro-water, temperature and pressure in each gas chamber in a closed gas chamber. It is a digital SF6 gas density and micro-water comprehensive online monitoring and diagnosis system for the condition maintenance of power SF6 switch station. Dew point measurement range: -50~+20℃ Temperature measurement range: -40~+60℃ Pressure measurement range (absolute pressure): 100 ~ 1200kPa Dew point measurement accuracy: ±3℃td (for details, see measurement accuracy and measurement conditions under pressure) Temperature measurement accuracy: 0~+50℃ ±0.5℃ -40~+80℃ ±1℃ Pressure measurement accuracy: 0~+50℃ ±0.5% -40~+60℃±0.75% Calculation parameters: gas pressure value (SF6 gas) at 20°C 100~1200kPa The density of SF6 or SF6/N2 mixed gas is 0~100kg/m³ PPM micro water content calculated according to volume concentration 40~40000ppm Dew point value converted to atmospheric pressure -65~+20℃ output: Digital output: RS485 interface (isolated) Digital output interface baud rate: 9600bps Digital output protocol: modbus Interface connector specification: relay socket connector Use environment: Temperature: -40~+60℃(-40~+140F)   Relative humidity: 0~95%RH Pressure: 0~50bar a (725 psia) Measured gas: non-corrosive gas Working power supply: 18~28VDC Working current: 25mA during normal measurement 70mA when high temperature heating and clearing Shell material: stainless steel Sensor protection cap: stainless steel hollow protection cap Mechanical interface: G1/2 Protection class: IP65 Storage temperature range: -20~+80℃ The digital SF6 gas density and micro water comprehensive online monitoring and diagnosis system includes: 1. Distributed in the urban dispatch center or the remote client of any office desktop computer according to the user's needs (responsible for remote monitoring of the SF6 switch density and micro-water operation status in all substations within the jurisdiction), located in the power distribution cabinet of the main control building of the monitored substation The on-site monitoring server (mainly responsible for centralized data processing, monitoring and unified protocol to facilitate interface compatibility and encryption and decryption of remote transmission), SF6 density micro-water monitoring unit located on each switch body (to realize the gas density, micro-water monitoring unit in the switch body Sampling and data quantification of water and temperature, and complete transmission), a three-in-one integrated intelligent management and diagnosis system is formed for this purpose. 2. On the one hand, the SF6 density micro-water monitoring unit communicates and uploads the collected and quantified SF6 gas density and micro-water content data with the on-site monitoring server through RS485. On the other hand, it will be connected to the relay protection system in the main control room of the substation in the form of passive hard contacts, so that the density and micro-water data of each unit in the switching station can be remotely monitored, and the switching operation trend can be predicted. At the same time, the alarm and blocking protection control of density and sluggish water are linked (users can choose whether they are currently connected or not according to their needs). 3. The on-site monitoring server exchanges data with the host computer or remote computer in the form of power communication protocol or RS485. Realize digital sampling, on-site monitoring, central/main control room monitoring, remote dispatch center synchronous monitoring and management integrated SF6 gas density and micro-water comprehensive online monitoring and status diagnosis syst
Retail price
0.0
Market price
0.0
Number of views:
1000
Product serial number
Quantity
-
+
Stock:
0
Product description
Parameters

SF6 micro water density online monitoring device (WINFOSS-S6)

Original imported sensor, precise measurement, long life; patented sealing technology, zero leakage, effectively ensure the safety of high-voltage equipment!

product description

The SF6 micro-water density online monitoring device (WINFOSS-S6) is mainly used in the online monitoring of high-voltage electrical equipment using SF6 gas insulation in substations. The SF6 micro-water density online monitoring device can monitor the SF6 gas pressure, Density, temperature, dew point and PPM values. And provide SF6 gas moisture exceeded alarm function, density alarm. The data processing server automatically collects and stores monitoring data, and completely preserves the data trend (the data can be preserved for more than 15 years). The data processing server displays and processes the received data, and gives the test results and the change trend curve. The monitoring data and alarm signals can be uploaded to the upper-level monitoring center or the background of the fortune monitoring in real time.

SF6 micro-water density online monitoring device (WINFOSS-S6) transmission monitoring unit integrates three sensors and a micro-circulation system. The SF6 micro-water density online monitoring product in high-voltage switchgear mainly solves the problem of online monitoring of micro-water, temperature and pressure in each gas chamber in a closed gas chamber. It is a digital SF6 gas density and micro-water comprehensive online monitoring and diagnosis system for the condition maintenance of power SF6 switch station.

Dew point measurement range: -50~+20℃

Temperature measurement range: -40~+60℃
Pressure measurement range (absolute pressure): 100 ~ 1200kPa
Dew point measurement accuracy: ±3℃td (for details, see measurement accuracy and measurement conditions under pressure)
Temperature measurement accuracy: 0~+50℃ ±0.5℃
-40~+80℃ ±1℃
Pressure measurement accuracy: 0~+50℃ ±0.5%
-40~+60℃±0.75%
Calculation parameters: gas pressure value (SF6 gas) at 20°C 100~1200kPa
The density of SF6 or SF6/N2 mixed gas is 0~100kg/m³
PPM micro water content calculated according to volume concentration 40~40000ppm
Dew point value converted to atmospheric pressure -65~+20℃

output:

Digital output: RS485 interface (isolated)
Digital output interface baud rate: 9600bps
Digital output protocol: modbus
Interface connector specification: relay socket connector

Use environment:
Temperature: -40~+60℃(-40~+140F)  
Relative humidity: 0~95%RH
Pressure: 0~50bar a (725 psia)
Measured gas: non-corrosive gas
Working power supply: 18~28VDC
Working current: 25mA during normal measurement
70mA when high temperature heating and clearing
Shell material: stainless steel
Sensor protection cap: stainless steel hollow protection cap
Mechanical interface: G1/2
Protection class: IP65
Storage temperature range: -20~+80℃

The digital SF6 gas density and micro water comprehensive online monitoring and diagnosis system includes:

1. Distributed in the urban dispatch center or the remote client of any office desktop computer according to the user's needs (responsible for remote monitoring of the SF6 switch density and micro-water operation status in all substations within the jurisdiction), located in the power distribution cabinet of the main control building of the monitored substation The on-site monitoring server (mainly responsible for centralized data processing, monitoring and unified protocol to facilitate interface compatibility and encryption and decryption of remote transmission), SF6 density micro-water monitoring unit located on each switch body (to realize the gas density, micro-water monitoring unit in the switch body Sampling and data quantification of water and temperature, and complete transmission), a three-in-one integrated intelligent management and diagnosis system is formed for this purpose.
2. On the one hand, the SF6 density micro-water monitoring unit communicates and uploads the collected and quantified SF6 gas density and micro-water content data with the on-site monitoring server through RS485. On the other hand, it will be connected to the relay protection system in the main control room of the substation in the form of passive hard contacts, so that the density and micro-water data of each unit in the switching station can be remotely monitored, and the switching operation trend can be predicted. At the same time, the alarm and blocking protection control of density and sluggish water are linked (users can choose whether they are currently connected or not according to their needs).
3. The on-site monitoring server exchanges data with the host computer or remote computer in the form of power communication protocol or RS485. Realize digital sampling, on-site monitoring, central/main control room monitoring, remote dispatch center synchronous monitoring and management integrated SF6 gas density and micro-water comprehensive online monitoring and status diagnosis system, and regularly output operating status diagnosis report.

 

Service Guarantee

A. Provide on-site installation, commissioning and training guidance, and carry out on-site demonstration operations.

B. Provide detailed Chinese manual and user guide.

C. One year free warranty, lifetime spare parts support and maintenance.

D. The hotline is available 365 days a day to answer users' inquiries.

Scan the QR code to read on your phone
We could not find any corresponding parameters, please add them to the properties table
Username used for comment:
客户留言
Description:
验证码
韦弗斯检测技术

Service Line:400-668-3536
Robte : 13585763546
Tel:+86-21-60195869
E-mail:SF6@winfoss.com

Quick Navigation

Subscribe to News

If you are interested in our products, you can follow us!

Follow Us
feedback feedback feedback feedback

底部版权

Time of issue:2021-11-25 13:36:06

Privacy Statement  Terms and Conditions  Copyright © Winfoss Seeker Technology (Shanghai) Co., Ltd. All  沪ICP备15031711号 沪公网安备31011802004953号 Power By:www.300.cn

搜索
Search